Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pdesignc
2.00 kW
SEER
9.47
Qce
74.00 kWh/annum
SEER Class
A+++
Pdesignh
2.30 kW
SCOP
5.20
SCOP Class
A+++
Qhe
619.00 kWh/annum
LwO env
58 dB(A)
LwI1 env
54 dB(A)
Pc
2.00 kW
Pec
0.37 kW
EER
5.35
Pc @ 30°C
1.48 kW
EER @ 30°C
8.25
Pc @ 25°C
1.20 kW
EER @ 25°C
11.89
Pc @ 20°C
1.20 kW
EER @ 20°C
15.30
Ph
2.50 kW
Peh
0.50 kW
COP
5.00
Ph @ -7°C
2.04 kW
COP @ -7°C
3.53
Ph @ +2°C
1.24 kW
COP @ 2°C
5.23
Ph @ +7°C
0.87 kW
COP @ +7°C
6.28
Ph @ +12°C
0.97 kW
COP @ +12°C
7.95
Tbiv
-10 °C
Ph TBiv
2.30 kW
COP @ Tbiv
3.22
TOL
-10.00 °C
Ph E
2.30 kW
COP E
3.22
Poff
1.00 W
Psb
1.00 W
Pto
7.00 W
Pck
0.00 W
Psbh
1.00 W
Ptoh
8.00 W
LRcontminc
0.60
CcpLRcontminc
2.22
LRcontminh
0.35
CcpLRcontminh
1.26
Refrigerant
R32
Refr. Line
5 m m
Main Power Supply
230-1-50
Mounting
Wall mounted
Capacity Control
variable
Corresponding Pipe Length
10.0000 m
Factory Refrigerant Charge
0.9500 kg
Inverter
true
Eligible CEE
true