Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
2.00 kW
EER
4.08
Pec
0.49 kW
Ph
2.70 kW
Peh
0.65 kW
COP
4.15
Pdesignc
2.00 kW
SEER
7.00
SEER Class
A++
Qce
100.00 kWh/annum
Pc PL CondB
1.49 kW
EER PL CondB
6.40
Pc PL CondC
1.26 kW
EER PL CondC
9.01
Pc PL CondD
1.34 kW
EER PL CondD
12.20
Pdesignh
1.90 kW
SCOP
4.60
SCOP Class
A++
Qhe
578.00 kWh/annum
Ph PL CondA
1.72 kW
COP PL CondA
3.10
Ph PL CondB
1.01 kW
COP PL CondB
4.65
Ph PL CondC
0.85 kW
COP PL CondC
6.00
Ph PL CondD
1.02 kW
COP PL CondD
7.50
TOL
-15.0000 °C
Ph PL CondE TOL
1.62 kW
COP PL CondE TOL
2.25
Tbiv
-10 °C
Ph PL CondF Tbiv
1.90 kW
COP PL CondF Tbiv
2.55
Psbc
1.00 W
Poffc
1.00 W
Ptoc
29.00 W
Pckc
0.00 W
Poffh
1.00 W
Ptoh
29.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
61 dB(A)
LwI1 env
53 dB(A)
IU Names
CS-TZ20WKEW
No. of IU
1
IU Range Names
CS-TZ20WKEW
Mounting
Wall mounted
Refrigerant
R32
Factory Refrigerant Charge
0.5400 kg
Refr. Line
5 m
Corresponding Pipe Length
5.0000 m
Main Power Supply
230-1-50
Capacity Control
Variable
Eligible CEE
true