Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pdesignc
3.40 kW
SEER
6.20
Qce
191.00 kWh/annum
SEER Class
A++
Pdesignh
2.40 kW
SCOP
4.30
SCOP Class
A+
Qhe
781.00 kWh/annum
LwO env
64 dB(A)
LwI1 env
60 dB(A)
Pc
3.40 kW
Pec
1.21 kW
EER
2.81
Pc @ 30°C
2.60 kW
EER @ 30°C
4.50
Pc @ 25°C
1.80 kW
EER @ 25°C
7.80
Pc @ 20°C
1.00 kW
EER @ 20°C
13.00
Ph
3.60 kW
Peh
0.98 kW
COP
3.69
Ph @ -7°C
2.20 kW
COP @ -7°C
3.00
Ph @ +2°C
1.30 kW
COP @ 2°C
4.20
Ph @ +7°C
0.80 kW
COP @ +7°C
5.40
Ph @ +12°C
1.00 kW
COP @ +12°C
6.70
Tbiv
-10 °C
Ph TBiv
2.40 kW
COP @ Tbiv
2.60
TOL
-10.00 °C
Ph E
2.40 kW
COP E
2.60
Poff
4.00 W
Psb
4.00 W
Pto
6.00 W
Poffh
4.00 W
Psbh
4.00 W
Ptoh
12.00 W
Refrigerant
R32
Refr. Line
5m m
Main Power Supply
230-1-50
Mounting
Wall mounted
Corresponding Pipe Length
7.0000 m
Factory Refrigerant Charge
0.4500 kg
Inverter
true
Eligible CEE
true