eurovent-logo
linkedin-header twitter-header facebook-header instagram-header
  • Biz kimiz?
  • contact us
  • English Français Español Italiano Русский Deutsch عربى Türkçe 简体中文
eurovent-logo
  • Sertifikasyon
  • Hava kalitesi ve havalandırma
  • Termal konfor
  • Isı pompası
  • Soğutma
  • Yönetmelik
  • Enerji verimliliği
  • News
  • Sertifikalı ürünlerinizi bulun
  • Biz kimiz?
  • contact us
  • English Français Español Italiano Русский Deutsch عربى Türkçe 简体中文
Yalnızca editoryal arama

products

No result

Makaleler

No result

Haberler

No result

Etkinlikler

No result

Teknik içgörü

No result

Ürünlerinizi sertifikalandırın

Sertifika programı

Kurumlar

Sertifika işaretleri

Sertifikasyon süreci

ProdBIM

ENERJİ VERİMLİLİĞİ ETİKETİ

Laboratuvarlar ve ajanslar

Sertifikalı ürün rehberi

  1. Anasayfa
  2. Haberler
  3. Recent changes in the certification programme for Air-to-Air Regenerative Heat Exchangers (AARE)

Haberler

Recent changes in the certification programme for Air-to-Air Regenerative Heat Exchangers (AARE)


Dec 7, 2022
facebook twitter linkedin
Dosyayı almak için lütfen formu doldurun





With more than 10 years of expertise gained in Air-to-Air Regenerative Heat Exchangers certification, Eurovent Certita Certification constantly tries to improve the value of the programme, answering the needs of a growing and demanding market. Every year, certified Air-to-Air Regenerative Heat Exchangers are selected and tested in an independent laboratory, providing trustworthy test results. These tests are then checked against the selection tools in order to ensure the reliability of provided data.

In 2014, Eurovent Certita Certification decided to change the way the results are checked, and aligned the method with EN308:1997:

  • Prior to 2014, the exhaust air inlet (11) and the supply air inlet (21) airflows were used as inputs in the selection tools.
  • Since 2014, the exhaust air inlet (11) and supply air outlet (22) airflows have been used as inputs in the selection tools.

As the airflow on the supply air outlet (22) is usually lower than the airflow on the supply air inlet (21), due to the Outdoor Air Correction Factor[1] (OACF), the air velocity across the exchanger is lower: the calculation thus gives a better efficiency. Therefore it is more likely that the efficiency will be out of the certification tolerances (defined in Rating Standard RS 8/C/002-2016). These changes have impacted the certified performances. In particular, the certified efficiencies (both temperature and humidity) have globally decreased when the products have remained identical. By using this method, Eurovent Certita Certification is closer to the customers’ expectations, whose requirements are on the airflows coming from and to the building, and in line with the EN308:1997, as the performances are checked with balanced airflows (the tests are conducted in order to keep exhaust air inlet (11) and the supply air outlet (22) airflows balanced). 


[1] OACF; for more details, see Eurovent 17/11 - 2015: Guidelines for Heat Recovery

icon-footer-brand-1
icon-footer-brand-2
icon-footer-brand-3
Daha fazlasını bul
logo-footer
NAVIGASYON
Hava kalitesi ve havalandırma Termal rahatlık Isı pompası Soğutma
Yönetmelik Mali teşvikler Enerji verimliliği
Haberler Etkinlikler
SİTE HARİTASI SSS YASAL BILGI TICARI MARKALAR OLAY LISTESI BIZ KIMIZ? BIZE ULAŞIN
All rights reserved@ Eurovent Certita Certification linkedin-header twitter-header facebook-header instagram-header