Eurovent Certified Performance vs Passivhaus


Exploring residential ventilation product performance certifications

Two of the most well know residential ventilation product certifications for Mechanical Ventilation with Heat Recovery (MVHR) systems are Passivhaus Component Certification and Eurovent Certified Performance. While both play important and distinct roles in verifying the performance of systems, both differ in focus, performance criteria, application, certification process and regulatory compliance with the EU's Ecodesign requirements for Energy-related Products (ErP) and the Energy Performance of Buildings Directive (EPBD).

Therefore, it is crucial that those making product decisions know the difference in scope between the certifications.

Passivhaus overview

Created by the Passivhaus Institute (PHI), the purpose of Passivhaus component certification is to ensure that ventilation systems meet the high energy efficiency and airtightness standards of Passivhaus (Passive House) buildings. The certification is aimed at ventilation devices with heat recovery for use in ultra-low energy buildings that require minimal heating and cooling.

Passivhaus offers ventilation component certification under five categories:

  • Ventilation systems (< 600 m3/h)
  • Ventilation systems (> 600 m3/h)
  • Decentralised ventilation systems (single room only / with second room connection)
  • Decentralised ventilation systems (school room)
  • Exhaust air wall systems.

Using PHI test standards, the key assessment criteria include:

  • Heat recovery rate
  • Electric power consumption
  • Comfort criterion
  • Internal and external leakage
  • Acoustic performance
  • Room air hygiene (filter)
  • Frost protection.

PHI defines an air volume range in which the unit matches Passivhaus demands and can be used in Passive Houses. Therefore, Passivhaus certified products are primarily used in Passivhaus-certified buildings.

Eurovent Certified Performance overview

Created By Eurovent Certita Certification, the purpose of Eurovent Certified Performance is to independently and impartially verify manufacturers’ product performance and energy efficiency data.

The Eurovent Certified Performance programme for Residential Air Handing Units is aimed at Mechanical Ventilation with Heat Recovery (MVHR) systems. The programme is open to units:

  • With any type of heat recovery system (including recuperative heat exchangers, regenerative heat exchangers, and extract air / outdoor air heat pumps)
  • With flow rates between 250 and 1000 m³/h
  • Plus, the unit must be suitable for residential buildings. The intended use cannot be exclusively for a non-residential ventilation application.

Using the globally recognised EN 13141-7+A1:2025 test standard, the key characteristics certified include:

  • Leakage class
  • Aeraulic performances
  • Airflow/pressure curves
  • Maximum airflow [m³/h]
  • Electrical consumption [W]
  • Specific Power Input SPI [W/(m³/h)]
  • Temperature efficiency / COP
  • Performances at cold climate conditions
  • SEC (Specific Energy Consumption) in [kWh/(m²/y]
  • A-weighted global sound power levels [dB(A)].

Eurovent Certification’s ‘Certify-all’ rule means that when joining the programme, the manufacturer has three years to ensure all relevant units presented on the European market are certified. Manufacturers cannot pick and choose flagship models – all products in the range must pass certification criteria and stay compliant - even entry level models.

Eurovent Certified products are for use in all building types, not just ultra-low-energy buildings.

Key Differences Summary

 

Feature Passivhaus component certification Eurovent Certified Performance for Residential Air Handling Units
Focus Part of the Passivhaus ecosystem: 
Passivhaus certified products are used in the Passive House Planning Package (PHPP) to develop Passivhaus buildings.

All residential applications:

Eurovent Certified products hold independently verified product performance and energy efficiency data which aligns with European regulations.

Certification process
  • Testing in an independent, accredited third-party laboratory
  • Validation of documentation
  • Performance modelling via Passive House Planning Package.
  • Testing in an independent, accredited third-party laboratory
  • Factory audits (as of 2026)
  • Validation of all submitted data and documentation.
Impartial product selection

NO

Units are selected and prepared by the manufacturer.

YES

Units are randomly selected by Eurovent Certification with no manufacturer intervention.

Frequency of product testing Once Every 2 years for each type of heat recovery
EN 13141-7+A1:2025 Test standard The EN 13141-7 test standard is used to calculate the energy use of the complete building.

The EN 13141-7+A1:2025 test standard is used to test product performance and align with Ecodesign.

Surveillance process Random spot checks. Comprehensive conformity checks, including website checks. Plus, from 2026 the process will include factory audits every 2 years.
Certify-all

NO

Manufacturers can choose which models to certify.

YES

All applicable units in the range must be certified within 3 years.

Regulatory role Supports the Passivhaus building standard. Supports compliance with European legislation (e.g., EU Ecodesign) ensuring that HVAC appliances and the buildings they are installed in fulfil all necessary legal requirements and standards including the Energy Performance of Buildings Directive (EPBD).
Application Products for use in Passivhaus-certified buildings. Products for use in all residential applications.

 

Reliability of performance data

Impartiality

To be impartial and attain accurate test data, all bias needs to be removed from the certification procedure, as does any opportunity for those both inside and outside of the process to influence any results.

Eurovent Certification has strict rules on product selection for laboratory tests. Eurovent Certification randomly selects products direct from the production line, factory stock or point of sale so it is sure that the unit tested is the same as units available on the market. The manufacturer cannot choose or prepare the unit and has no direct contact with the laboratory. Eurovent Certification also ensures that laboratories and their staff have no prior affiliation, or a conflict of interest, with the manufacturer or product they are testing.

During the Passivhaus process, it is manufacturers who select and supply the unit for laboratory testing. This means manufacturers also have direct contact with the laboratory. Passivhaus process therefore allows the manufacturer to select the tested unit - this differs from Eurovent’s random selection methodology.

Cross checking data

Eurovent Certification checks the manufacturer’s data and compares it with the test report. A certificate will only be issued if the manufacturer provides correct data. This extra layer of verification ensures that manufacturer data wherever it is used (e.g. marketing brochures, technical sheets, manufacturer website) corresponds with the tested data. This sets Eurovent-certified manufacturers apart, as it’s proven that manufacturers are reliable in the truthful data that they provide. This is not standard practice for all certification providers.

 

Understanding the scope of regulatory compliance

The EU Ecodesign for Sustainable Products Regulation 2014/1781 (ESPR) lays down a framework for product-specific regulations outlining energy efficiency, performance, and sustainability requirements for HVAC products across the European market. The EN 13141-7+A1:2025 standard defines performance testing methods for residential ventilation units, specifically focusing on heat recovery ventilation (HRV) and MVHR systems.

EN 13141-7+A1:2025 aligns with Ecodesign requirements, covering parameters such as:

  • Thermal efficiency (including real-world installation losses)
  • Fan power consumption under defined test conditions
  • Sound power levels
  • Pressure drop and airflow performance.

Testing to EN 13141-7+A1:2025 ensures the unit meets harmonised EU efficiency requirements, allowing it to be legally sold under Ecodesign regulations.

The Eurovent Certified Performance programme uses EN 13141-7+A1:2025 to provide ErP-compliant performance data, allowing manufacturers to prove that their products meet EU energy efficiency and market requirements, ensuring legal compliance while proving product performance. While both programmes use EN 13141-7+A1:2025, Eurovent Certified Performance is specifically aligned with Ecodesign regulation requirements, whereas the PHI adapts the standard to suit its building energy modelling framework.

Passivhaus focusses on heat recovery efficiency and SFP (Specific Fan Power) at a given air volume. Whereas Ecodesign requirements regulate the Specific Energy Consumption (SEC), which includes all power-consuming components, such as fans and controls. Additionally, the Passivhaus component certification scope does not include ErP-specific labelling or the full testing standards required to be sold in the EU. It also doesn’t regulate as strictly additional requirements for noise levels, controls, and information disclosure. Indeed, the PHI expect that the tested unit already meets international and local regulatory demands prior to testing.

Passivhaus component certification therefore does not offer the same regulatory guarantees as Eurovent Certified Performance.

Conclusion

Both certifications play very distinct and important roles within the industry. While Passivhaus component certification is essential for Passivhaus projects, Eurovent Certified Performance offers a broader certification for all residential projects.

Eurovent Certified Performance provides:

  • Impartially verified performance data, with no manufacturer interference
  • Full disclosure across the entire product range – not just flagship products
  • Guaranteed performance and energy efficiency across a range of building types – not just ultra sustainable buildings
  • Compliance with ErP and EPBD.

Passivhaus component certification provides:

  • Performance data verified to Passivhaus Standards
  • Assurance products are compliant with Passivhaus requirements
  • Data that can be directly imported into the Passive House Planning Package for energy modelling and system integration.

It is therefore important that specifiers and system designers understand the purpose and limitations of both certifications.

Discover more about Eurovent Certified Performance for Residential Air Handing Units:

View and compare Eurovent certified products

View the programme overview

View programme technical information

 

Disclaimer

This content is provided for information purposes only. It offers a general comparison between Eurovent Certified Performance and Passivhaus Component Certification, based on their respective scopes, objectives, and methodologies, using publicly available information. It does not replace official certification rules, technical documentation, or contractual documents issued by Eurovent Certita Certification or the Passive House Institute. Only official certification rules and certificates define the scope, conditions, and validity of certification, which may evolve over time.