Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
3.40 kW
EER
4.23
Pec
0.80 kW
Ph
4.50 kW
Peh
1.15 kW
COP
3.91
Pdesignc
3.40 kW
SEER
8.19
SEER Class
A++
Qce
145.00 kWh/annum
Pc PL CondB
2.51 kW
EER PL CondB
5.87
Pc PL CondC
1.62 kW
EER PL CondC
9.63
Pc PL CondD
1.25 kW
EER PL CondD
15.60
Pdesignh
2.80 kW
SCOP
4.68
SCOP Class
A++
Qhe
837.00 kWh/annum
Ph PL CondA
2.48 kW
COP PL CondA
3.24
Ph PL CondB
1.51 kW
COP PL CondB
4.72
Ph PL CondC
1.17 kW
COP PL CondC
5.98
Ph PL CondD
1.19 kW
COP PL CondD
7.28
TOL
-20.0000 °C
Ph PL CondE TOL
2.12 kW
COP PL CondE TOL
2.95
Tbiv
-7 °C
Ph PL CondF Tbiv
2.48 kW
COP PL CondF Tbiv
3.24
Psbc
1.00 W
Poffc
1.00 W
Ptoc
7.00 W
Pckc
0.00 W
Psbh
1.00 W
Poffh
1.00 W
Ptoh
8.00 W
Pckh
0.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
58 dB(A)
LwI1 env
53 dB(A)
LRcontminc
0.48
CcpLRcontminc
2.28
LRcontminh
0.26
CcpLRcontminh
1.53
IU Names
FVXM35B
No. of IU
1
IU Range Names
FVXM
Mounting
Floor standing
Refrigerant
R32
Factory Refrigerant Charge
0.9500 kg
Refr. Line
5 m
Corresponding Pipe Length
10.0000 m
Main Power Supply
230-1-50
Capacity Control
variable
Eligible CEE
true