Pompes à chaleur Air-Air - Air/air, multi split, réversible (≤ 12 kW)

Model FDC71VNX/FDUM40VH/FDUM40VH

Gamme

VNX/VSX (AC1 multi)

N° de diplôme

17.02.279

Participant

2208

Brand

MHI Thermal Systems

Pc

7.10 kW

EER

3.53

Pec

2.01 kW

Ph

8.00 kW

Peh

1.91 kW

COP

4.19

Pdesignc

7.10 kW

SEER

5.61

SEER Class

A+

Qce

691.81 kWh/annum

Pc PL CondB

5.23 kW

EER PL CondB

5.13

Pc PL CondC

3.37 kW

EER PL CondC

8.64

Pc PL CondD

3.20 kW

EER PL CondD

11.85

Pdesignh

5.90 kW

SCOP

4.05

SCOP Class

A+

Qhe

2419.00 kWh/annum

Ph PL CondA

6.20 kW

COP PL CondA

2.62

Ph PL CondB

3.85 kW

COP PL CondB

3.99

Ph PL CondC

2.45 kW

COP PL CondC

5.33

Ph PL CondD

2.56 kW

COP PL CondD

6.56

TOL

-20.0000 °C

Ph PL CondE TOL

5.00 kW

COP PL CondE TOL

2.09

Tbiv

-7 °C

Ph PL CondF Tbiv

6.20 kW

COP PL CondF Tbiv

2.62

Psbc

15.00 W

Poffc

15.00 W

Ptoc

45.13 W

Pckc

22.00 W

Ptoh

35.00 W

SCOP Class C

G

SCOP Class W

G

LwO env

66 dB(A)

LwI1 duct

60 dB(A)

LwI2 duct

60 dB(A)

LRcontminh

0.31

CcpLRcontminh

1.27

No. of IU

2

Mounting

Ducted

Refrigerant

R410A

Refr. Line

5 m

Main Power Supply

230-1-50

Capacity Control

Variable

Eligible CEE

true