Air conditioners - Air to air, split, reversible (≤ 12 kW)

Model NISEKO MURALE IM42-NS / E1U42L-NS

نطاق

NISEKO MURALE

رقم الدبلوم

21.03.105

Participant

Thermor

Brand

THERMOR

Pc

4.80 kW

EER

2.81

Pec

1.71 kW

Ph

4.80 kW

Peh

1.33 kW

COP

3.60

Pdesignc

4.80 kW

SEER

6.30

SEER Class

A++

Qce

267.00 kWh/annum

Pc PL CondB

3.54 kW

EER PL CondB

4.25

Pc PL CondC

2.27 kW

EER PL CondC

7.35

Pc PL CondD

1.01 kW

EER PL CondD

13.50

Pdesignh

3.60 kW

SCOP

4.00

SCOP Class

A+

Qhe

1260.00 kWh/annum

Ph PL CondA

3.18 kW

COP PL CondA

2.40

Ph PL CondB

1.94 kW

COP PL CondB

4.00

Ph PL CondC

1.25 kW

COP PL CondC

5.35

Ph PL CondD

0.95 kW

COP PL CondD

6.25

TOL

-10.0000 °C

Ph PL CondE TOL

3.10 kW

COP PL CondE TOL

2.30

Tbiv

-7 °C

Ph PL CondF Tbiv

3.18 kW

COP PL CondF Tbiv

2.40

Psbc

2.00 W

Poffc

2.00 W

Ptoc

10.00 W

Pckc

0.00 W

Psbh

2.00 W

Poffh

2.00 W

Ptoh

15.00 W

Pckh

0.00 W

SCOP W

5.10

SCOP Class W

A+++

Qhe W

824.00 kWh/annum

LwO env

65 dB(A)

LwI1 env

60 dB(A)

IU Names

AS50RCBHRA-4

No. of IU

1

IU Range Names

Revive Plus

Mounting

Wall mounted

Refrigerant

R32

Factory Refrigerant Charge

0.7800 kg

Refr. Line

5m m

Main Power Supply

230-1-50

Capacity Control

Variable

Eligible CEE

true