Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
9.50 kW
EER
3.26
Pec
2.91 kW
Ph
10.80 kW
Peh
2.45 kW
COP
4.40
Pdesignc
9.50 kW
SEER
6.55
SEER Class
A++
Qce
507.00 kWh/annum
Pc PL CondB
7.00 kW
EER PL CondB
4.75
Pc PL CondC
4.50 kW
EER PL CondC
7.93
Pc PL CondD
3.84 kW
EER PL CondD
11.96
Pdesignh
8.70 kW
SCOP
4.30
SCOP Class
A+
Qhe
2828.00 kWh/annum
Ph PL CondA
7.70 kW
COP PL CondA
2.50
Ph PL CondB
4.68 kW
COP PL CondB
4.35
Ph PL CondC
3.26 kW
COP PL CondC
5.84
Ph PL CondD
3.52 kW
COP PL CondD
6.64
TOL
-15.0000 °C
Ph PL CondE TOL
7.65 kW
COP PL CondE TOL
2.45
Tbiv
-7 °C
Ph PL CondF Tbiv
7.70 kW
COP PL CondF Tbiv
2.50
Psbc
3.00 W
Poffc
3.00 W
Ptoc
6.00 W
Pckc
0.00 W
Psbh
3.00 W
Poffh
3.00 W
Ptoh
12.00 W
Pckh
0.00 W
LwO env
70 dB(A)
LwI1 env
58 dB(A)
IU Names
AUXG36KRLB
No. of IU
1
IU Range Names
AUY**K
Mounting
Cassette
Refrigerant
R32
Factory Refrigerant Charge
1.9000 kg
Refr. Line
5,0 m m
Corresponding Pipe Length
30.0000 m
Main Power Supply
230-1-50
Capacity Control
Valiable
Eligible CEE
true