Air conditioners - Air to air, split, reversible (≤ 12 kW)

Model AOHG09KPCA/ASHG09KPCA

Gamma

ASH**L

Diploma

94.01.198

Participant

30

Brand

GENERAL

Pc

2.50 kW

EER

3.52

Pec

0.71 kW

Ph

2.80 kW

Peh

0.79 kW

COP

3.54

Pdesignc

2.50 kW

SEER

6.70

SEER Class

A++

Qce

131.00 kWh/annum

Pc PL CondB

1.84 kW

EER PL CondB

5.26

Pc PL CondC

1.18 kW

EER PL CondC

9.11

Pc PL CondD

1.18 kW

EER PL CondD

11.80

Pdesignh

2.40 kW

SCOP

4.00

SCOP Class

A+

Qhe

840.00 kWh/annum

Ph PL CondA

2.12 kW

COP PL CondA

2.25

Ph PL CondB

1.29 kW

COP PL CondB

4.16

Ph PL CondC

0.83 kW

COP PL CondC

5.19

Ph PL CondD

0.88 kW

COP PL CondD

6.28

TOL

-15.0000 °C

Ph PL CondE TOL

2.13 kW

COP PL CondE TOL

2.24

Tbiv

-7 °C

Ph PL CondF Tbiv

2.12 kW

COP PL CondF Tbiv

2.25

Psbc

5.00 W

Poffc

5.00 W

Ptoc

1.00 W

Pckc

0.00 W

Psbh

5.00 W

Poffh

5.00 W

Ptoh

9.00 W

Pckh

0.00 W

SCOP Class C

G

SCOP Class W

G

LwO env

59 dB(A)

LwI1 env

58 dB(A)

IU Names

ASYG025KPCA

No. of IU

1

IU Range Names

ASY**K

Mounting

Wall mounted

Refrigerant

R32

Factory Refrigerant Charge

0.6000 kg

Refr. Line

5,0 m m

Corresponding Pipe Length

15.0000 m

Main Power Supply

230-1-50

Capacity Control

Valiable

Eligible CEE

true