Heat pumps NF - Air to water, heating, cooling, and hot water
LwO Env
65 dB(A)
LwI Env
49 dB(A)
Pdesignh (W55)
3.60 kW
SCOPnet (W55)
3.52
SCOP (W55)
3.49
ηs,h (W55)
138.00 %
Pdesignc
4.50 kW
SEER
3.95
Ph
3.96 kW
Pe
1.53 kW
COP
2.59
Ph
3.74 kW
Pe
1.11 kW
COP
3.37
Ph
5.82 kW
Pe
1.38 kW
COP
4.22
Ph
3.73 kW
Pe
1.81 kW
COP
2.06
Ph
3.67 kW
Pe
1.34 kW
COP
2.74
Ph
5.38 kW
Pe
1.66 kW
COP
3.24
Ph
3.45 kW
Pe
2.35 kW
COP
1.47
Ph
3.40 kW
Pe
1.55 kW
COP
2.19
Ph
5.53 kW
Pe
2.19 kW
COP
2.53
Pc
4.50 kW
Pe
1.66 kW
EER
2.71
Pc
7.41 kW
Pe
2.56 kW
EER
2.90
TOL (W55)
-10.00 °C
COP E (W55)
1.52
Tbiv (W55)
-10.00 °C
PhF (W55)
3.60 kW
COP F (W55)
1.52
Taux
1.09 %
Psbh
15.00 W
reference code
7642728
HP Detailed reference
AWHP 6 MR-2 & BALLON 200 PSL HYBRID 4-8 & FSC. 19
Tank Detailed reference
7623188-200 ESL HYBRID 4-8 EH500
LRcontmin
35.90 %
Ccp LRcontmin
1.02 %
Main Power Supply
230-1-50
Liquid Refrigerant
R410A
Type
Split
Location
Indoor
Tc
55 °C
Tapping Cycle NF (EN 16147)
L
Running Mode
Alternating
Nominal Stockage Volume
177 l
th
0h0min
Pes
35.00 W
0' (WH)
53.10 °C
V40
254 l
Qelec
4.29 kWh/day
AEC
899.00 kWh/annum
COP (DHW)
2.72
η WH
114.00 %
th
0h0min
Compressor system
Variable
Compressor Type
Rotary