Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
6.00 kW
EER
3.39
Pec
1.77 kW
Ph
7.00 kW
Peh
1.94 kW
COP
3.61
Pdesignc
6.00 kW
SEER
6.90
SEER Class
A++
Qce
304.00 kWh/annum
Pc PL CondB
4.43 kW
EER PL CondB
4.82
Pc PL CondC
2.85 kW
EER PL CondC
8.09
Pc PL CondD
1.93 kW
EER PL CondD
13.26
Pdesignh
4.80 kW
SCOP
4.30
SCOP Class
A+
Qhe
1562.00 kWh/annum
Ph PL CondA
4.26 kW
COP PL CondA
2.68
Ph PL CondB
2.63 kW
COP PL CondB
4.31
Ph PL CondC
1.67 kW
COP PL CondC
5.64
Ph PL CondD
1.96 kW
COP PL CondD
6.82
TOL
-20.0000 °C
Ph PL CondE TOL
3.12 kW
COP PL CondE TOL
2.04
Tbiv
-7 °C
Ph PL CondF Tbiv
4.26 kW
COP PL CondF Tbiv
2.68
Psbc
1.00 W
Poffc
1.00 W
Ptoc
12.00 W
Pckc
0.00 W
Psbh
1.00 W
Poffh
1.00 W
Ptoh
14.00 W
Pckh
0.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
63 dB(A)
LwI1 env
60 dB(A)
IU Names
FTXM60R
No. of IU
1
IU Range Names
FTXM
Mounting
Wall mounted
Refrigerant
R32
Factory Refrigerant Charge
1.1500 kg
Refr. Line
5 m
Corresponding Pipe Length
10.0000 m
Main Power Supply
230-1-50
Capacity Control
variable
Eligible CEE
true