Residential ventilation Eurovent - Rotary heat exchangers

Model CL4 RER

Bereich

Nordic

Diplom-Nummer

19.12.007

Participant

FLEXIT AS

Brand

Flexit

Internal Leakage class

B3

External Leakage class

B3

Airflow-pressure certified window

Download file

ptUd

100

qv max

0.1128 m³/s

ptUD/2

50

qv ref

0.0790 m³/s

Pe ref

119.00 W

SPI

0.42 W/(m³/h)

Temp. Ratio

82.00 %-point

Lw casing

48 dB(A)

Lw supply

66 dB(A)

Lw extract

55 dB(A)

Lw exhaust

66 dB(A)

Lw outdoor

55 dB(A)

Temp.Ratio@TOL

72.43 %-point

Disbalance ratio

11.68

qv Cold

0.0790 m³/s

Cold Climate (true/false)

true

SEC

-39.70 kWh/m².a

SEC Class

A

AEC

222.00 kWh/annum

AHS Average

4528.00 kWh/annum

AHS Cold

8857.00 kWh/annum

AHS Warm

2047.00 kWh/annum

MISC

1.10

CTRL

0.65

x-value

2.00

Filter class supply

ePM1 55%

Filter class exhaust

ePM1 55%