Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
9.40 kW
EER
3.50
Pec
2.69 kW
Ph
11.20 kW
Peh
3.25 kW
COP
3.45
Pdesignc
9.40 kW
SEER
5.50
SEER Class
A
Qce
591.00 kWh/annum
Pc PL CondB
7.00 kW
EER PL CondB
4.20
Pc PL CondC
4.60 kW
EER PL CondC
7.60
Pc PL CondD
3.90 kW
EER PL CondD
9.80
Pdesignh
8.00 kW
SCOP
4.00
SCOP Class
A+
Qhe
2745.00 kWh/annum
Ph PL CondA
7.00 kW
COP PL CondA
2.80
Ph PL CondB
4.30 kW
COP PL CondB
4.10
Ph PL CondC
3.00 kW
COP PL CondC
5.00
Ph PL CondD
3.20 kW
COP PL CondD
6.70
TOL
-15.0000 °C
Ph PL CondE TOL
4.50 kW
COP PL CondE TOL
2.00
Tbiv
-7 °C
Ph PL CondF Tbiv
7.00 kW
COP PL CondF Tbiv
2.80
Psbc
22.00 W
Poffc
22.00 W
Ptoc
50.00 W
Poffh
22.00 W
Ptoh
73.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
70 dB(A)
LwI1 env
65 dB(A)
IU Names
PSA-M100KA
No. of IU
1
IU Range Names
PSA
Mounting
Floor standing
Refrigerant
R32
Factory Refrigerant Charge
3.1000 kg
Refr. Line
5m m
Corresponding Pipe Length
30.0000 m
Main Power Supply
400-3-50
Capacity Control
Variable
Eligible CEE
true