Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
5.00 kW
EER
3.80
Pec
1.32 kW
Ph
6.00 kW
Peh
1.58 kW
COP
3.80
Pdesignc
5.00 kW
SEER
6.10
SEER Class
A++
Qce
287.00 kWh/annum
Pc PL CondB
3.60 kW
EER PL CondB
5.80
Pc PL CondC
2.30 kW
EER PL CondC
7.90
Pc PL CondD
2.30 kW
EER PL CondD
10.60
Pdesignh
3.80 kW
SCOP
4.10
SCOP Class
A+
Qhe
1279.00 kWh/annum
Ph PL CondA
3.40 kW
COP PL CondA
3.00
Ph PL CondB
2.00 kW
COP PL CondB
4.20
Ph PL CondC
1.40 kW
COP PL CondC
4.90
Ph PL CondD
1.70 kW
COP PL CondD
6.10
TOL
-11.0000 °C
Ph PL CondE TOL
3.70 kW
COP PL CondE TOL
2.20
Tbiv
-10 °C
Ph PL CondF Tbiv
3.80 kW
COP PL CondF Tbiv
2.40
Psbc
17.00 W
Poffc
17.00 W
Ptoc
7.00 W
Poffh
17.00 W
Ptoh
24.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
65 dB(A)
LwI1 duct
57 dB(A)
IU Names
SEZ-M50DAL2
No. of IU
1
IU Range Names
SEZ
Mounting
Ducted
Refrigerant
R32
Factory Refrigerant Charge
2.0000 kg
Refr. Line
5m m
Corresponding Pipe Length
30.0000 m
Main Power Supply
230-1-50
Capacity Control
Variable
Eligible CEE
true