Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
5.00 kW
EER
4.17
Pec
1.20 kW
Ph
5.00 kW
Peh
1.18 kW
COP
4.23
Pdesignc
5.00 kW
SEER
7.40
SEER Class
A++
Qce
236.40 kWh/annum
Pc PL CondB
3.70 kW
EER PL CondB
6.02
Pc PL CondC
1.74 kW
EER PL CondC
10.37
Pc PL CondD
1.54 kW
EER PL CondD
12.38
Pdesignh
5.00 kW
SCOP
4.24
SCOP Class
A+
Qhe
1651.14 kWh/annum
Ph PL CondA
4.40 kW
COP PL CondA
2.84
Ph PL CondB
2.70 kW
COP PL CondB
4.24
Ph PL CondC
1.75 kW
COP PL CondC
5.39
Ph PL CondD
0.78 kW
COP PL CondD
5.21
TOL
-25.0000 °C
Ph PL CondE TOL
4.05 kW
COP PL CondE TOL
2.67
Tbiv
-7 °C
Ph PL CondF Tbiv
4.40 kW
COP PL CondF Tbiv
2.84
Psbc
12.00 W
Poffc
12.00 W
Ptoc
6.00 W
Pckc
0.00 W
Psbh
11.00 W
Poffh
11.00 W
Ptoh
12.00 W
Pckh
0.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
62 dB(A)
LwI1 env
55 dB(A)
IU Names
RCI-2.0FSR1
No. of IU
1
IU Range Names
RCI
Mounting
Cassette
Refrigerant
R32
Factory Refrigerant Charge
1.3000 kg
Refr. Line
5 m
Corresponding Pipe Length
30.0000 m
Main Power Supply
230-1-50
Capacity Control
Variable
Eligible CEE
true