Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pc
5.00 kW
EER
3.61
Pec
1.39 kW
Ph
6.00 kW
Peh
1.58 kW
COP
3.80
Pdesignc
5.00 kW
SEER
7.30
SEER Class
A++
Qce
240.00 kWh/annum
Pc PL CondB
3.68 kW
EER PL CondB
5.08
Pc PL CondC
2.37 kW
EER PL CondC
8.90
Pc PL CondD
2.12 kW
EER PL CondD
13.90
Pdesignh
4.60 kW
SCOP
4.40
SCOP Class
A+
Qhe
1463.00 kWh/annum
Ph PL CondA
4.07 kW
COP PL CondA
2.76
Ph PL CondB
2.48 kW
COP PL CondB
4.46
Ph PL CondC
1.59 kW
COP PL CondC
5.69
Ph PL CondD
1.60 kW
COP PL CondD
7.11
TOL
-15.0000 °C
Ph PL CondE TOL
3.15 kW
COP PL CondE TOL
2.39
Tbiv
-7 °C
Ph PL CondF Tbiv
4.07 kW
COP PL CondF Tbiv
2.76
Psbc
1.00 W
Poffc
1.00 W
Ptoc
13.00 W
Pckc
0.00 W
Psbh
1.00 W
Poffh
1.00 W
Ptoh
12.00 W
Pckh
0.00 W
SCOP Class C
G
SCOP Class W
G
LwO env
61 dB(A)
LwI1 env
59 dB(A)
IU Names
FTXP50N
No. of IU
1
IU Range Names
FTXP
Mounting
Wall mounted
Refrigerant
R32
Factory Refrigerant Charge
0.9000 kg
Refr. Line
5 m
Corresponding Pipe Length
10.0000 m
Main Power Supply
230-1-50
Capacity Control
variable
Eligible CEE
true