Air conditioners - Air to air, split, reversible (≤ 12 kW)
Pdesignc
5.30 kW
SEER
7.60
Qce
244.00 kWh/annum
SEER Class
A++
Pdesignh
4.30 kW
SCOP
4.20
SCOP Class
A+
Qhe
1433.00 kWh/annum
LwO env
65 dB(A)
LwI1 env
60 dB(A)
Pc
5.30 kW
Pec
1.47 kW
EER
3.60
Pc @ 30°C
3.79 kW
EER @ 30°C
5.60
Pc @ 25°C
2.40 kW
EER @ 25°C
9.10
Pc @ 20°C
1.65 kW
EER @ 20°C
16.20
Ph @ -7°C
3.75 kW
COP @ -7°C
3.15
Ph @ +2°C
2.23 kW
COP @ 2°C
3.96
Ph @ +7°C
1.43 kW
COP @ +7°C
5.20
Ph @ +12°C
1.65 kW
COP @ +12°C
7.02
Tbiv
-10 °C
Ph TBiv
4.30 kW
COP @ Tbiv
2.72
TOL
-10.00 °C
Ph E
4.30 kW
COP E
2.72
Poff
6.00 W
Psb
6.00 W
Pto
2.00 W
Ptoh
14.00 W
Inverter
true
Refrigerant
R32
Refr. Line
5 m
Main Power Supply
230-1-50
Mounting
Wall mounted
Factory Refrigerant Charge
1000.0000 kg
IU Names
true
Eligible CEE
true