Air conditioners - Air to air, split, reversible (≤ 12 kW)

Model HDHC-070N-09M25/YDAC-070R-09M25

Bereich

HDH

Diplom-Nummer

03.01.247

Participant

1400

Brand

AIRWELL

Pc

7.00 kW

EER

3.95

Pec

1.77 kW

Ph

7.50 kW

Peh

2.02 kW

COP

3.71

Pdesignc

7.00 kW

SEER

8.50

SEER Class

A+++

Qce

288.00 kWh/annum

Pc PL CondB

4.81 kW

EER PL CondB

6.00

Pc PL CondC

3.11 kW

EER PL CondC

10.13

Pc PL CondD

2.13 kW

EER PL CondD

16.43

Pdesignh

5.00 kW

SCOP

4.20

SCOP Class

A+

Qhe

1666.00 kWh/annum

Ph PL CondA

4.42 kW

COP PL CondA

2.97

Ph PL CondB

2.75 kW

COP PL CondB

4.26

Ph PL CondC

1.76 kW

COP PL CondC

4.96

Ph PL CondD

2.02 kW

COP PL CondD

6.33

TOL

-10.0000 °C

Ph PL CondE TOL

4.18 kW

COP PL CondE TOL

2.76

Tbiv

-7 °C

Ph PL CondF Tbiv

4.42 kW

COP PL CondF Tbiv

2.97

Psbc

1.00 W

Poffc

1.00 W

Ptoc

17.00 W

SCOP Class C

G

SCOP Class W

G

LwO env

68 dB(A)

LwI1 env

65 dB(A)

Mounting

wall-mounted

Refrigerant

R32

Factory Refrigerant Charge

1.5000 kg

Refr. Line

5 m

Main Power Supply

230-1-50

Capacity Control

variable

Eligible CEE

true